Section 08630 (METAL FRAMED SKYLIGHTS)

  • METAL FRAMED SKYLIGHTS // BY SOLAR INNOVATIONS

    ** NOTE TO SPECIFIER ** Solar Innovations, Inc.; aluminum and wood framed skylights.

    This section is based on the products of Solar Innovations, Inc., which is located at:

    31 Roberts Road
    Pine Grove, PA 17963
    Tel. Toll Free: (800) 618-0669
    Tel: (570) 915-1500
    Fax: (570) 915-6083
    E-mail: skylight@solarinnovations.com
    www.solarinnovations.com

    Solar Innovations, Inc. is a leading manufacturer of the highest quality aluminum and wood structures. Their comprehensive product line also includes conservatories, greenhouses, solariums, skylights, pool and spa enclosures, folding glass walls, walkways, canopies, terrace doors and more. Solar Innovations, Inc. strives to produce products tailored to each particular need, residential or commercial.

    This specification includes Solar Innovations, Inc. aluminum and wood framed skylights that are available in any size, design, or color with custom or standard options, at comparable prices to their competitors.


  • (required)
  • (required)
  • (required)
  • PART 1 GENERAL

    1.1 Section Includes

    ** NOTE TO SPECIFIER ** Select items below required for project.


  • 1.2 Related Sections

    ** NOTE TO SPECIFIER ** Select any sections below relevant to this project; add others as required.






  • 1.3 References

    ** NOTE TO SPECIFIER ** Select references from the list below that are not actually required by the text of the edited section.






  • 1.4 DESIGN / PERFORMANCE REQUIREMENTS




































  • 1.5 SUBMITTALS

    A. Submit under provisions of Section 01300.

    B. Product Data: Manufacturer's data sheets on each product to be used, including:

    1. Product details.

    2. Preparation instructions and recommendations.

    3. Storage and handling requirements and recommendations.

    4. Installation methods.

    C. Shop Drawings: Detailed drawings and structural calculations prepared specifically for the project by manufacturer; provide stamp or seal of licensed professional engineer if required by authorities having jurisdiction.

    1. Indicate material thickness, fastener locations, glazing and hardware arrangements.

    2. Include schedule identifying each unit, with marks or numbers referencing drawings.

    3. Must show all surrounding substrates and relevant conditions.

    4. Must be drawn in the domestic USA, by the manufacturer of the system.

    ** NOTE TO SPECIFIER ** Select selection samples if colors have already been selected.






  • 1.6 QUALITY ASSURANCE

    A. Manufacturer Qualifications:

    1. Company specializing in manufacturing products specified in this Section with minimum twelve (12) years experience in fabrication and erection of glazed window wall systems for projects of similar scope.

    2. Manufacturer must be recognized by NAMI.

    3. Manufacturer must use extruded aluminum system that uses domestically produced aluminum, and is fabricated/assembled in the USA.

    B. Installer Qualifications:

    1. Experienced in performing work of this section that has specialized in installation of work similar to that required for the project.

    2. Manufacturer must approve installer of folding glass wall for warranty to be valid.

    3. Manufacturer may not withhold approval of installer for undue reasons.

    ** NOTE TO SPECIFIER ** Include a mock-up if the project size and/or quality warrant taking such a precaution. The following is one example of how a mock-up on a large project might be specified. When deciding on the extent of the mock-up, consider all the major different types of work on the project.





  • 1.7 DELIVERY, STORAGE, AND HANDLING

    A. Store products in manufacturer's unopened packaging until ready for installation.

    B. Protect factory finishes from damage, precipitation and construction materials until ready for installation.

  • 1.8 PROJECT CONDITIONS

    A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.

    B. Perform structural silicone sealant work when air temperature is above 10 degrees F (minus 12 degrees C).

  • 1.9 WARRANTY

    A. Provide skylight manufacturer's warranty that properly installed skylight will be free from significant defects in material, workmanship, and uncontrolled water leakage for five (5) years from date of Substantial Completion.

    ** NOTE TO SPECIFIER ** Select warranties below that apply to products specified.

    B. Finish:










  • ** NOTE TO SPECIFIER ** Under extreme conditions, warranties for glazing may be less than 10 years. Verify conditions with manufacturer. Select the following paragraph if not required; edit to suit conditions.


  • PART 2 PRODUCTS

    2.1 MANUFACTURERS

    A. Acceptable Manufacturer: Solar Innovations; 31 Roberts Road, Pine Grove, PA 17963. ASD. Tel: (800) 618-0669. Tel: (570) 915-1500. Fax: (570) 915-6083. Email: skylight@solarinnovations.com. www.solarinnovations.com.

    B. Manufacturing facility must have achieved Gold LEED certification.

    ** NOTE TO SPECIFIER ** Select one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.


  • 2.2 SKYLIGHTS

    B. Configuration/Size:

    1. Dimensions:

  • a. Width:
  • b. Length:
  • c. Projection:
  • d. Height:
  • ** NOTE TO SPECIFIER ** Select all but one of the following configuration descriptions. Please note that some performance is configuration specific.
  • 1. Configuration:








  •  h. Configuration:
  • B. Framing Members

    ** NOTE TO SPECIFIER ** Edit paragraphs appropriately.
















  • ** NOTE TO SPECIFIER ** Select two of the following three paragraphs. Polycarbonate is also available; verify system compatibility, color and thickness prior to specifying.




  •  4. Other:
  • ** NOTE TO SPECIFIER ** Many code jurisdictions have their own local code requirements. Provide local code requirements under which the project is being designed; i.e. Uniform Building Code, 1997 Edition with local amendments. If project location has only national code jurisdiction, indicate as such.

  • 2.3 MATERIALS

    ** NOTE TO SPECIFIER ** The exterior of the wood system is clad in aluminum. Select this paragraph for both wood and aluminum framing systems.





  • ** NOTE TO SPECIFIER ** The manufacturer will select the type of glazing for the project based on project location, site, use of skylight, and input from the Architect. If glazing type has been determined, modify following to indicate type, thickness, tint if any, and other specific requirements. Coordinate with glazing described above.






  • ** NOTE TO SPECIFIER ** Select the following when required.

  • ** NOTE TO SPECIFIER ** Verify with manufacturer if internal reinforcing is required based on framing material, size and configuration.
















  • 2.4 FABRICATION

    A. Fabricate components in accordance with approved shop drawings. Remove burrs and rough edges. Shop fabricate to greatest extent practicable to minimize field cutting, splicing, and assembly. Disassemble only to extent necessary for shipping and handling limitations. Install gaskets and tapes in factory.

    B. Welding:

    1. Comply with recommendations of American Welding Society.

    2. Grind exposed welds smooth and flush with adjacent surfaces before finishing; restore mechanical finish.

    ** NOTE TO SPECIFIER ** Select the following if internal reinforcing is required for this project.



  • D. Fabricate components true to detail and free from defects impairing appearance, strength, or durability. Contour outdoor horizontal or purlin glazing retainers to minimize water ponding and ice or snow buildup.

    E. Fabricate components to allow for accurate and rigid fit of joints and corners. Match components carefully ensuring continuity of line and design. Ensure joints and connections will be flush and weather tight. Ensure slip joints make full, tight contact and are weather tight.

    F. Reinforce components at anchorage and support points, at joints, and at attachment points for interfacing work.

    G. Glass: Accurately size glass to fit openings allowing clearances following recommendations of "Glazing Manual" published by Flat Glass Marketing Association.

    H. Cut glass clean and carefully. Nicks and damaged edges will not be accepted. Replace glass that has damaged edges.

  • 2.5 FINISHES

    ** NOTE TO SPECIFIER ** Select one of the following aluminum finishes. If more than one finish is required, indicate the locations where each is to be used. Verify current standard colors available.
























  • ** NOTE TO SPECIFIER ** If a custom color or a different type of finish is required, verify availability with manufacturer and enter a description below.
  •  E. Aluminum Finish:
  •  1. Aluminum Liquid Finish:
     2. Aluminum Powder Finish:
     3. Aluminum Anodized Finish:
     4. Metal Cladding:
  • ** NOTE TO SPECIFIER ** Select the following paragraph if no wood members are required.




  • PART 3 EXECUTION

    3.1 EXAMINATION

    A. Do not begin installation until substrates have been properly prepared.

    B. If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.

  • 3.2 PREPARATION

    A. Clean surfaces thoroughly prior to installation.

    B. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.

    C. If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding. Work by Others. However, it is the installers responsibility to notify the Contractor and Architect if conditions are inappropriate for proper installation.

  • 3.3 INSTALLATION

    A. Install skylight system in accordance with approved shop drawings and manufacturer's instructions..

    B. Separate dissimilar materials using non-conductive tape, paint, or other material not visible in finished work.

    C. Provide attachments and shims to permanently fasten system to building structure.

    D. Maintain dimensional tolerances and alignment with adjacent work.

    E. Anchor securely in place, allowing for required movement, including expansion and contraction.

    F. Install glazing and sealants in accordance with manufacturer's instructions without exception, including surface preparations.

    G. Set sill members in bed of sealant. Set other members with internal sealants to provide weather tight construction.

    H. Install flashings, bent metal closures, corners, gutters, and other accessories as required or detailed.

    I. Clean surfaces and install sealant in accordance with sealant manufacturer's instructions and skylight manufacturer's guidelines.

  • Label for Content Area

    3.4 PROTECTION

    A. Protect installed products until completion of project.

    B. Touch-up, repair or replace damaged products before Substantial Completion.

Back to Top

All text, graphics, images, animation, videos, and other works on this website are the copyrighted works of Solar Innovations, Inc. All Rights Reserved. Any unauthorized redistribution or reproduction of any copyrighted materials on this website is strictly prohibited. The trademarks, logos, and service marks (collectively the "Trademarks") displayed on the website are Trademarks of Solar Innovations, Inc. and/or its affiliates. Some Trademarks appear on the website with permission from their respective owners. Nothing contained on the website should be construed as granting any license or right to use any Trademark displayed on the website. Unauthorized use of the Trademarks is strictly prohibited and may constitute trademark infringement. All drawings included in this website are the exclusive sole property of Solar Innovations, Inc., and are considered both confidential and proprietary. Any use of the information, design or drawings contained herein for any purpose whatsoever without the expressed written consent of a Solar Innovations, Inc. authorized individual is forbidden.